The following files are made available for people who wish to test their JCAMP-DX programs. Some have come from Bob McDonald, others from Tony Davies, Peter Lampen, Scott Van Bramer and some from our labs here in Jamaica.
The JCAMP-DX standard allows for a variety of file formats which include:
Files containing equally spaced abscissa (X) values.
##XYDATA= (X++(Y..Y))
FIXed format files in increasing or decreasing abscissa order.
PACed format " w or w/out DUP "
SQZ format " w or w/out DUP "
DIF format " w or w/out DUP "
and non-compressed files containing a simple column of XY pairs.
Non-equally spaced X values but continuous plot
##XYPOINTS= (XY..XY)
and tables
##PEAKTABLES= (XY..XY)
among others.
Examples of these (supposedly error free) files are given here:
If you do find errors in any of these files please
let me know.
fixinc1.jdx (IR-T)
fixdec1.jdx (IR-T)
Fixed format, increasing and decreasing abscissa respectively.
fixinc2.jdx (IR-A)
fixdec2.jdx (NMR)
fixinc3.jdx - a sine curve (1-360).
fixdec3.jdx - a sine curve (360-1).
fixinc4.jdx - a simple curve.
fixinc5.jdx - a simulated titration curve.
Fixed format, increasing and decreasing abscissa respectively.
jtpolys.jdx (IR-T)
Fixed format, increasing abscissa.
pacdec1.jdx (IR-T)
PACed format, decreasing abscissa. Note that the difference between FIX and PAC is that no
multiple blanks are between Y values. In the example given, no blanks at all are between
the Y values either a '+' or a '-' is used as the delimiter.
I don't have any examples of PACDUP files, anyone out there seen any??
sqzdec1.jdx (NMR)
An example of a file that uses only the SQZ compression type. Note that this file has a
very long header record and a large number of data points so may take a few minutes to
load.
sqzdupd1.jdx (IR-T)
An example of a file that contains both SQZ and DUP delimiters.
dupinc1.jdx (IR-A)
dupdec1.jdx (IR-T)
DIFDUP format, increasing and decreasing abscissa respectively.
dupinc2.jdx (IR-T)
dupdec2.jdx (IR-T)
DIFDUP format, increasing and decreasing abscissa respectively.
jtpolysd.jdx (IR-T)
DIFDUP format, increasing abscissa.
xyinc1.jdx (IR-T)
xyinc2.jdx (EPR)
Single column of XY pairs, increasing abscissa.
pktab1.jdx (MS)
pktab2.jdx (MS)
Examples of PEAK TABLES, non continuous display.
CHIME vs 2 will cope with multiple BLOCKS and an extra menu option is available to select which BLOCK is to be displayed.
I include here some files with MULTIPLE BLOCKS:
blckpac1.jdx (Vis)
An example of a kinetic run using PAC'd Vis spectra (5 data blocks).
blckpkt1.jdx (MS)
An example of a series of Mass Spectra recorded with different Ionization energies (6 data
blocks).
compound.jdx (IR-T)
An example of some FTIR's in DIFDUP format (5 data blocks).
CHIME vs 2 will cope with NTUPLES and an extra menu option is available to select which PAGE is to be displayed.
NMR data, especially from Bruker instruments, have often been recorded using the NTUPLE
format defined in the vs 5.0 specs for JCAMP-DX.
The following 14 data files are for o-dichlorobenzene. The first 10 are spectra and show
real (1-5) and complex (6-10) spectra at different levels of compression. The remaining 4
are FID's.
Spectra o01.jdx FIX - real only o06.jdx FIX - complex (real and imaginary) o02.jdx DIF o07.jdx DIF o03.jdx PAC o08.jdx PAC o04.jdx SQZ o09.jdx SQZ o05.jdx DIFDUP o10.jdx DIFDUP FID's ofid1.jdx FIX ofid3.jdx SQZ ofid2.jdx PAC ofid4.jdx DIFDUP
Some examples of files that contain common errors such as incorrect number of points given in the header, a line missing, or invalid data are given below.
Note that ##T_ITLE=, ##TITLe=, ##T\I/T_L e= should ALL be interpreted as ##TITLE=. That is, when reading the file you must strip out spaces hyphens, underscores and convert to UPPERCASE before comparison of the labels. ##JCAMP_DX=, ##JCAMP-DX= and ##JCAMPDX= are again, all allowed and equivalent.
efim1.jdx
efip1.jdx
This is file fixinc2.jdx but with 1 less or more point listed in the header than is
actually present in the file.
efifx1.jdx - increasing X
efilx1.jdx
efdfx1.jdx - decreasing X
efdlx1.jdx
These files have the header values for FIRSTX and LASTX given incorrectly.
ecp2fe.jdx
There are no JCAMP-DX specifications for cyclic voltammetry but the following gives an
example of what might be possible. Since the scan is cyclic from 0 volt back to 0 volt.
FIRSTX and LASTX are identical and do NOT match the maximum and minimum values. The only
way I could get to display the file was by setting INCORRECT values for FIRSTX and LASTX
and reading in the data as ##XYPOINTS.
efibi1.jdx
ttest.jdx
fixed format but contains spaces, $$ comments in data lines and invalid data symbol (?)
included.
efidp1.jdx
This has one data point out by a factor of 10000. The resulting graph looks like it has
only 1 point, but try a zoom.
dtest.jdx
DIFDUP format but contains spaces, $$ comments in data lines and invalid data symbol (?)
included.
Bob McDonald has summarised the problem of END-OF-LINE (NEW-LINE) DETECTION:
I quote
"Section 4.3 of V4.24 indicates that JCAMP-DX lines should be terminated by < crlf
>. In MSDOS, < crlf > is the standard, but UNIX uses < lf > alone, and the
Macintosh uses < cr > alone. Actually, most PC software handles either < crlf
> or < lf >, but not < cr >. It is not convenient to use non-standard
end-of-line on any of these systems. Some data transfer protocols handle the conversion
between conventions. Documentation should warn prospective users of this problem so that
they can choose the appropriate option of the data transmission protocol or disk
conversion program".
mactab1.jdx
mactab2.jdx
These files were copied to a MAC as ASCII text and then sent back as BINARY. This meant
that all < crlf >'s were converted to < cr > alone. The plugin should read
them successfully, since we stream the data.
Note that the Bruker program, WinNMR, despite the fact that it runs under Windows, does not use the < crlf > convention. The files therefore can NOT be easily edited using a simple ASCII editor like Notepad since they contain < lf > as end of line markers. The argument is that most Bruker users are Unix based so the files are written to conform to Unix.
If you encounter difficulties with software reading Bruker files then try converting from < lf > to < crlf >. One way to do this easily is to FTP them to a UNIX machine and FTP them back again. The sequence must be to FTP them as BINARY then FTP them back as ASCII text.